Skip to content
Sahara Link Group
Menu

Diesel generators

Four brands covering home backup through industrial prime power. SLG Engineering sizes the set to the load, supplies it, and stays on the phone after commissioning.

Generator supply

Brands
Perkins, Cummins, Ricardo, EVOL
Duty
Standby and prime
Enclosure
Soundproof canopy or open-type
Scope
Supply, installation, maintenance

Duty

How often the set runs decides the engine, the cooling and the service interval.

Standby
Sits idle and takes the load when the grid drops. The common case in Bangladesh.
Prime
Runs as the main supply for long periods where grid power is absent or unreliable.
Commercial
Offices, malls, hotels and mixed-use buildings, usually with an automatic transfer switch.
Industrial
Factories and plants where a stopped line costs more than the genset.

Configuration

Decided at quotation, not after delivery. Getting these wrong is the usual reason a genset disappoints.

Soundproof canopy
Low-noise enclosure for rooftops and built-up sites.
Open-type set
For plant rooms where noise is already contained.
Automatic transfer switch
Hands the load over without anyone present.
Capacity sizing
Matched to connected load, starting current and future headroom.
Perkins-powered diesel generator in a soundproof canopy

Perkins

Dependable power when it matters

Perkins-powered diesel gensets for standby and prime duty across commercial and critical sites.

Perkins — supply summary

Type
Diesel generator
Applications
Commercial, Industrial, Residential, Critical infrastructure
Supplied by
SLG Engineering

Engine protection

Low oil pressure monitoring
Protects the engine against inadequate lubrication.
High coolant temperature protection
Prevents continued operation during abnormal overheating.
Overspeed protection
Available on selected engine series to respond to excessive speed.
Electronic shut-off
Supports controlled engine shutdown when required.
Coolant-level monitoring
Available on selected electronic engine configurations.
Engine sensor and ECM monitoring
Selected electronic series continuously monitor critical operating parameters.

Equipment varies according to engine and genset configuration.

Cummins power generation set in an equipment hall

Cummins

Power you can count on

Cummins power generation for demanding applications, with PowerCommand control.

Cummins — supply summary

Type
Diesel generator
Applications
Standby, Prime, Commercial, Industrial
Supplied by
SLG Engineering

Control and protection

PowerCommand control
Integrated monitoring and generator control.
AmpSentry protection
Generator-set protection designed around electrical operating conditions.
Automatic fault detection
Monitors system conditions and identifies abnormal operation.
Alarm and status monitoring
Clear operating information for technicians and operators.
Automatic shutdown on critical faults
Protects equipment when critical conditions are detected.
Voltage and frequency regulation
Supports stable generator output.

Functions depend on the Cummins genset and controller configuration.

Ricardo diesel generator in a soundproof canopy

Ricardo

Robust power. Practical performance.

Ricardo diesel gensets for prime and standby duty in commercial and industrial settings.

Ricardo — supply summary

Type
Diesel generator
Applications
Prime power, Standby power, Commercial, Industrial
Supplied by
SLG Engineering

Controller protection

Low oil pressure shutdown
Protects the engine when lubrication pressure falls below safe levels.
High coolant temperature shutdown
Prevents operation during abnormal overheating.
Engine overspeed protection
Responds to excessive engine speed conditions.
Over and under voltage protection
Monitors abnormal voltage conditions.
Overload and overcurrent protection
Electrical protection under heavy load conditions.
Emergency stop
Immediate shutdown in emergency situations.
Start-failure alarm
Alerts operators when the generator does not start correctly.
Automatic transfer system option
Automatic switching to backup power when configured.

Protection depends on the generator controller and selected configuration. Confirm the final specification before ordering.

EVOL diesel generator outside a commercial building at night

EVOL

Power that keeps you moving

EVOL diesel gensets for standby and prime duty, from home backup to industrial load.

EVOL — supply summary

Type
Diesel generator
Applications
Commercial, Residential, Industrial, Construction
Supplied by
SLG Engineering

Protection functions

Low oil pressure protection
Shuts down the generator to prevent damage from insufficient oil pressure.
High coolant temperature protection
Shuts down when coolant temperature exceeds safe limits.
Engine overspeed protection
Prevents engine damage in the case of overspeed.
Overload and overcurrent protection
Protects the generator and connected equipment from high current.
Voltage monitoring
Continuously monitors output voltage for a stable, safe supply.
Emergency stop
Quick manual shutdown in an unsafe condition.
Battery and charging monitoring
Monitors battery voltage and charging for reliable starting.
Automatic transfer capability
Supports automatic transfer between utility and generator.

Confirm the final protection set from the specification sheet of the selected EVOL generator.

Tell us the load, we will size the set

Connected load, starting current, run hours and site conditions are enough to come back with a specification.

Start an enquiry